Sensors in the slab: notes from a first season of structural health monitoring
What worked, what froze, and what we learned about data we did not plan to collect.
- Par
- Mostafa Ser

Cet article n’est pas encore disponible dans votre langue. Vous lisez la version anglaise.
Last autumn our team instrumented two bridge decks with temperature, relative humidity and corrosion-potential sensors. The goal was modest: collect one full winter of data at the depth of the top reinforcement, and test whether low-cost hardware could survive.
Installation
Sensors were installed in cored holes and grouted with a repair mortar of similar permeability to the parent concrete. Each deck has a data logger powered by a small solar panel and a battery sized for three weeks without sun.
What failed
Two connectors corroded within six weeks, both at points where the cable sheath had been nicked during installation.
One logger lost a week of data when its battery fell below the cut-off voltage during a cold spell at minus 31 °C.
Snow-clearing equipment damaged an exposed cable run at the deck edge.
What surprised us
The number of freeze-thaw cycles at the depth of the reinforcement was much lower than the number of air temperature cycles. Thermal mass damps short events. This matters, because many laboratory protocols use air temperature cycles as their reference.
The concrete experiences a calmer winter than the air above it, but a wetter one.
Next season we will add moisture sensors at two depths and compare the field record with our accelerated laboratory protocol.
Mots-clés
À lire aussi
Pourquoi les tabliers de ponts au Canada vieillissent plus vite que prévu
Une durée de vie de 75 ans est une promesse que la plupart des tabliers canadiens ne tiennent pas. Les causes sont connues séparément, mais leur interaction reste mal modélisée.

Mesurer le carbone intrinsèque du béton : ce que les chiffres omettent
Les déclarations environnementales facilitent la comparaison des mélanges. Comparer des ouvrages est plus difficile, car la durabilité et les quantités comptent autant que le mélange.

Enseigner le béton armé par la rupture plutôt que par les formules
Les étudiants appliquent les équations normatives bien avant de comprendre ce contre quoi elles protègent. Montrer la rupture d’abord change l’ordre de l’apprentissage.